Material Science
Solutions for Thermal & Thermophysical Analysis

 

Simultaneous Thermogravimetry- Differential Scanning Calorimetry (STA/TG-DSC)

STA 449 F3 Jupiter®

 

Fascinating Flexibility in Thermal Analysis

 

The simultaneous thermal analyzer NETZSCH STA 449 F3Jupiter® allows the measurement of mass changes and thermal effects between -150°C and 2400°C.

 

The high flexibility caused by the various sensors, the great variety of sample crucibles and the wide TGA-measuring range make the system applicable for analysis of all kinds of materials including also inhomogenous substances.

 

Easily interchangeable sample holders allow the optimal system adaption to the diverse application areas (TGA, TGA-DTA and TGA-DSC measurements).

 

Various furnaces, easy interchangeable by the user, cover the complete temperature range (please see accessories).

Through to the vacuum tight design measurements at defined atmospheres (e.g. inert) are possible. The system is controlled by a newly developed integrated digital electronic device.

The analysis of measuring data runs under a standard PC and the well-proven Windows® software.

 

Technical Specification:

 

Design: Top-loading

 

Temperature range: -150°C to 2400°C

 

Furnace: Variety of furnaces incl. high-speed, water-vapor, low to highest temperature, e.g., silver, platinum, tungsten, etc.

 

Motorized furnace hoist: Double hoist for two furnaces or one furnace + automatic sample changer

 

Heating rate:

· 0.001 to 50 K/min (furnace-dependent)

· High-speed furnace: up to 1000 K/min

 

Sensors: TGA, TGA-DTA, TGA-DSC, TGA-DSCcp, special sensors for hanging samples. Sensors can be changed out easily in a matter of moments

 

Vacuum-tight: 10-4 mbar

 

AutoVac: Option for software-controlled automatic evacuation

 

Evacuation system:

Options for one and two furnaces; manual or software-controlled operation

 

Atmospheres: Inert, oxidizing, static, dynamic, vacuum

 

Oxygen trap system (OTS®): Optional

 

Automatic sample changer (ASC): 20 crucible positions (optional)

 

Gas flow control: Integrated frits (optional 3 mass flow controllers)

 

Temperature resolution: 0.001 K

 

Balance resolution: 0.01 µg(over the entire weighing range)

 

Balance drift: < 5 μg/hour

 

Maximum sample load: 35000 mg (incl. crucible), corresponds to TGA measuring range

 

Sample volume (max.)

· TGA: up to 5 ml

· DSC: 0.19 ml

· DTA: 0.9 ml

 

You may also be interested in:

Tel (GL): +603 - 7845 1111 | Fax: +603 - 7842 1112 | Service Hotline:  012-223 7074