Laboratory Microfluidics Mixer for mRNA/DNA lipid/polycation nanoparticle preparation (max. pressure 500 psi)

NanoMixer Microfluidic Mixing System:
NanoMixer is a precision microfluidic mixing platform designed for laboratory-scale preparation of mRNA, DNA, and siRNA delivery systems. It is an electrically driven, benchtop instrument that operates without the need for compressed air or hydraulic oil. The NanoMixer enables programmable flow rates (0–10 mL/min per pump) and controlled mixing ratios using gastight syringes (1 mL, 2.5 mL, 5 mL, or 10 mL), with configurations available for dual (NanoMixer), triple (NanoMixer-Triplex), or quadruple (NanoMixer-Quad) component blending.
Each NanoMixer model is equipped with independent syringe pumps, a PLC control system, and mixing modules that ensure reproducible and uniform formulation. With a working pressure up to 500 psi and temperature tolerance up to 80°C, the system supports sterile, dead-volume-minimized mixing suitable for sensitive biopharmaceutical applications.
Applications of NanoMixer Microfluidic Mixer:
mRNA/DNA/siRNA delivery formulations
Nanoemulsions and liposomes
Fat emulsions
Cell disruption and nanoparticle suspensions
Multi-component formulation development
Performance Features of NanoMixer:
Precision Mixing: Programmable ratio and speed control with ±0.1 mL inlet accuracy
Modular Design: Available in 2, 3, or 4-pump configurations for dual, ternary, or quaternary blending (A+B, A+B+C, A+B+C+D). The quaternary pump configuration also supports continuous microfluidic blending of A+B by allocating two pumps for continuous feeding of component A and two pumps for component B.
Compact and Lightweight: Integrated design (70×36×30 cm, 20–35 kg) suitable for benchtop use
Thermal Tolerance: Up to 80°C (176°F) for formulation stability
Digital Interface: Pressure display or analog pressure gauge options
Easy Cleaning: Flush-to-clean system
Compliant: CE and RoHS certified
Category:

Specifications

Catalog No. NanoMixer NanoMixer-Triplex NanoMixer-Quad
Flow Rate 0-10mL/min 0-10mL/min 0-10mL/min
Min. Sample 1mL 1mL 10mL
Max. Pressure 500psi
A+B=AB
500psi
A+B=AB+C=ABC
500psi
A+B=AB
A+B+C=ABC
A+B+C+D=ABCD
Dimensions(cm) 70 × 36 × 30 70 × 36 × 30 70 × 36 × 30
Weight 20 kg (44 lbs) 30 kg (66 lbs) 35 kg (77 lbs)
Max. Temp. 80ºC (176ºF)
Power 110V/220V
Cleaning Flush to clean
Application mRNA/DNA/siRNA delivery systems, Nano emulsion, fat emulsion, liposome, cell disruption, nano dispersion, microsphere
Features Digital display of pressure and flow rate

Features

Channel Y-type Microfluidic Mixing Chip  AB-Y; ABC-Y; ABCD-Y
Control System High pressure programming control systems: touch screen, speed control, auto stop control by volume, time, pressure or temperature, settable volume control as low as 0.2mL, display of flow rate and time, overload protection
Pressure Gauge Digital display on the touch screen
Inlet Type Luer
Outlet Type Luer
Inlet Reservoir 1mL gas tight syringe
Outlet Reservoir 10mL Tube
Product Material 316L stainless steel, tungsten carbide, viton, teflon
Material Standard Sanitary grade, FDA, GMP
Warranty 1 year against any manufacturing defects
Option Features
Channel NanoMixer Y-type (Single Line) Microfluidic chip: AB-Y; AB-YT;
NanoMixer S-type (Single strand like RNA) Microfluidic chip: AB-S; AB-ST;
NanoMixer X-type (Duplex strand like RNA) Microfluidic chip: AB-X; AB-XT;
NanoMixer-Triplex Y-type (Single Line) Microfluidic chip: ABC-Y; ABC-YT;
NanoMixer-Triplex S-type (Single strand like RNA) Microfluidic chip: ABC-S; ABC-ST;
NanoMixer-Triplex X-type (Duplex strand like RNA) Microfluidic chip: ABC-X; ABC-XT;
NanoMixer-Quad Y-type (Single Line) Microfluidic chip: ABCD-Y; ABCD-YT;
NanoMixer-Quad S-type (Single strand like RNA) Microfluidic chip: ABCD-S; ABCD-ST;
NanoMixer-Quad X-type (Duplex strand like RNA) Microfluidic chip: ABCD-X; ABCD-XT;
T: Heating/cooling jacket with built-in temperature sensor; 
Control System Please send the drawing if you need customized Microfluidic Chip
Detector Pressure gauge, pressure transducer, temperature transducer
Outlet type Tri-clamp or luer
Heat Exchanger Heating/cooling jacket with built-in temperature sensor
Inlet Reservoir 2.5mL, 5mL, 10mL gas tight syringe
Outlet Reservoir 2.5mL, 5mL, 10mL, 50mL, 100mL tube or gas tight syringe, S/S cylinder, jacketed glass cylinder or online
Cylinder Titanium high pressure cylinder (resistant to strong acid and base)

How to Use

FAQs and Tips

Troubleshooting:

Mechanical Faults

1.Backflow at Inlet
Symptom:
 Liquid flows back at the inlet while the syringe is in the extrusion stroke.
Cause: The inlet check valve has failed.
Solution: Replace the check valve.

2. Backflow at Outlet
Symptom:
 Liquid flows back at the outlet while the syringe is in the suction stroke.
Cause: The outlet check valve has failed.
Solution: Replace the check valve.

3. Microfluidic Chip Microchannel Blockage
Symptom:
 Sudden rise in internal system pressure causes connected capillaries to detach due to high pressure.
Cause: The microchannels on the chip surface are blocked.
Solution: Clean the chip microchannels.

4. Insufficient Suction Due to Air in Tubing
Symptom: 
The syringe does not fully fill, and air is present in the liquid.
Cause: Air is trapped inside the tubing system.
Solution: To degas the system, push the liquid upward in the syringe while loosening the outlet check valve to release trapped air.
Once the liquid flows steadily, tighten the valve, and repeat this process two to three times until all air is expelled.

Electrical Faults

1.Red Power Switch (PWR) Not Lit
1) Check if the fuse is blown; replace if necessary.
2) Check the device power connection; reconnect if faulty.
3) Check the wall socket; ensure the plug is fully inserted.

2. Clicking “Start” on the Main Interface Has No Response
1) Turn off the power and wait 30 seconds before restarting.
2) The system will rebuild, which takes a few seconds.
If the problem persists after restarting, contact after-sales service for assistance.

Equipment Maintenance

1. Repair and Preventive Maintenance
The required frequency of repair and preventive maintenance depends
on usage and the specific applications performed.
It is generally recommended to schedule maintenance and preventive
servicing at least once per year. Adhere to the recommended maintenance intervals.
If any component fails, it is recommended to replace it immediately to
prevent further damage to the system. Following these guidelines will help maximize the system’s service life.

2 Daily Cleaning
The syringe holder and chip bracket are the most common areas for spills, droplets, and material buildup. Surfaces can be wiped with ethanol or isopropanol. If fluid flows along the syringe holder into the interior of the instrument, there is no need to stop the machine during operation because the system is designed with a dry-wet separation; small amounts of liquid will not affect safety. After stopping the instrument, wipe the area with a clean, lint-free cloth. If fluid splashes onto the plastic housing, wipe it promptly to keep the exterior dry and avoid damage to the paint.

To clean the instrument body, cover, and all internal components, wipe surfaces with any of the following:
a. Warm water with a mild, non-abrasive detergent
b. Ethanol
c. Isopropanol

Use a soft cloth to wipe the surfaces, avoiding scratches that could affect the appearance of the instrument.