Material Science
Solutions for Thermal & Thermophysical Analysis
Simultaneous Thermogravimetry- Differential Scanning Calorimetry (STA/TG-DSC)


STA 449 F5 Jupiter®
A Sophisticated Instrument At A Very Attractive Price
Fully Equipped
This vacuum-tight STA 449 F5 Jupiter® is hand built specifically for your application. Each instrument comes pre-configured as you need it, with all of the hardware and software features that are required by high-temperature applications in the fields of ceramics, metals, inorganics, building materials, etc.
Best Cost-Performance-Ratio
The STA 449 F5 Jupiter® has high resolution, a high range, low drift balance and sensitive DSC capability that enables it to excel in all typical applications across a broad range of temperatures.
Unique Combination – True TG-DSC and TGA for High-Sample Volumes
True TGA and DSC measurements can be performed with high precision and reproducibility at sample temperatures from ambient to 1600°C. TGA measurements are also possible, even on large or heavy samples.
Top-loading – The Proven Design for Thermobalances
The STA 449 F5 Jupiter® is a top-loading system with a balance design that has been preferred for years in laboratories.
The reasons are simple: These systems combine ideal performance with easy handling.
Technical Specification:
Design: Top-loading
Temperature range: RT… 1600°C (sample temperature)
Furnace: SiC furnace on motorized hoist for safe, simplified operation
Heating rate: 0.001 to 50 K/min
Sensors:
· TGA-DSC (standard in system version I)
· TGA-DSCASC (standard for system version II with automatic sample changer)
· TGA (optional for up to large sample sizes)
· TGA-DTA (optional)
All sensors are easily interchangeable within seconds
Vacuum-tight: 10-2 mbar
AutoVac: Integrated for software-controlled automatic evacuation
Evacuation system: Yes
Atmospheres: Inert, oxidizing, static, dynamic, vacuum
Automatic sample changer (ASC): 20 crucible positions (standard for system version II)
Gas flow control: 3 mass flow controllers integrated for 1 protective and 2 purge gases
Temperature resolution: 0.001 K
Balance resolution: 0.01 µg(over the entire weighing range)
BeFlat® Integrated for flat baselines → considers buoyancy correction due to influences by crucible, atmosphere, heating rate, etc.
Balance drift: < 5 μg/hour
Maximum sample load: 35000 mg (incl. crucible), corresponds to TGA measuring range
Sample volume: Up to 5 cm³ (for TGA crucibles)
DSC enthalpy accuracy: ± 2% (for most materials)
Evolved gas analysis: QMS, GC-MS and/or FT-IR couplings (options)